Optimization of the working fluid in a Joule–Thomson cold stage

Share/Save/Bookmark

Derking, J.H. and Brake ter, H.J.M. and Sirbi, A. and Linder, M. and Rogalla, H. (2009) Optimization of the working fluid in a Joule–Thomson cold stage. Cryogenics, 49 (3-4). pp. 151-157. ISSN 0011-2275

[img]PDF
Restricted to UT campus only
: Request a copy
429Kb
Abstract:Vibration-free miniature Joule–Thomson (JT) coolers are of interest for cooling a wide variety of devices, including low-noise amplifiers, semiconducting and superconducting electronics, and small optical detectors used in space applications. For cooling such devices, coolers are needed which have operating temperatures within a wide temperature range of 2–250 K. In this paper, the optimization of the working fluid in JT cold stages is described that operate at different temperatures within that range. For each temperature, the most suitable working fluid is selected on the basis of the coefficient of performance of the cold stage, which is defined as the ratio of the gross cooling power to the change in Gibbs free energy of the fluid during compression. In addition, a figure of merit of the heat exchange in the counter-flow heat exchanger is evaluated that depends only on the properties of the working fluid.
Item Type:Article
Copyright:© 2009 Elsevier
Faculty:
Science and Technology (TNW)
Research Group:
Link to this item:http://purl.utwente.nl/publications/79341
Official URL:http://dx.doi.org/10.1016/j.cryogenics.2008.12.008
Export this item as:BibTeX
EndNote
HTML Citation
Reference Manager

 

Repository Staff Only: item control page

Metis ID: 265729