Frequency selection for air-coupled ultrasonic measurements in closed chambers
Jakevicius, L. and Demcenko, A. and Mardosaite, R. and Strelciunaite, V. (2010) Frequency selection for air-coupled ultrasonic measurements in closed chambers. In: 3rd international conference on radiation interaction with material and its use in technologies 2010, September 20-23, 2010, Kaunas, Lithuania.
| PDF 136Kb |
| Abstract: | In this work it is shown that a change in attenuation coefficient of ultrasound signal
depends on a nature of thermodynamic process when air-coupled ultrasonic measurements are carried out in closed systems. Therefore, for the air-coupled ultrasonic measurements in such systems, it is necessary to choose measurement system parameters in advance according to the thermodynamic process is taking place in the systems. |
| Item Type: | Conference or Workshop Item |
| Faculty: | Engineering Technology (CTW) |
| Research Chair: | |
| Research Group: | |