Theoretical comparison of packed bed and fluidized bed membrane reactors for methane reforming

Share/Save/Bookmark

Gallucci, Fausto and Sint Annaland van, Martin and Kuipers, J.A.M. (2010) Theoretical comparison of packed bed and fluidized bed membrane reactors for methane reforming. International Journal of Hydrogen Energy, 35 (13). pp. 7142-7150. ISSN 0360-3199

[img]PDF
Restricted to UT campus only
: Request a copy
628Kb
Abstract:In this theoretical work the performance of different membrane reactor concepts, both fluidized bed and packed bed membrane reactors, has been compared for ultra-pure hydrogen production via methane reforming. Using detailed theoretical models, the required membrane area to reach a given conversion and the prevailing temperature profiles have been compared. The extent of mass and heat transfer limitations in the different reactors has been evaluated, and strategies to decrease (or avoid) these limitations have been proposed for the fluidized bed membrane reactor concept. The results show that the packed bed membrane reactor requires in some conditions double membrane area with respect to the fluidized bed membrane reactor.

Item Type:Article
Copyright:© 2010 Professor T. Nejat Veziroglu
Research Group:
Link to this item:http://purl.utwente.nl/publications/73972
Official URL:http://dx.doi.org/10.1016/j.ijhydene.2010.02.050