Temperature development in the leakage flow of screw extruders

Share/Save/Bookmark

Meyer, H.E.H. and Ingen Housz, J.F. and Gorissen, W.C.M. (1978) Temperature development in the leakage flow of screw extruders. Polymer Engineering and Science, 18 (4). pp. 288-292. ISSN 0032-3888

open access
[img]
Preview
PDF
453kB
Abstract:Temperature distribution at the exit of the leakage gap is of interest for a number of problems. For the calculation of temperatures, the leakage flow may be considered to be a pure drag flow to a good approximation. In the Newtonian case, thermal development length may be expressed in terms of gap height as L ≈ 3/8Pe ·δ ;usually this is less than the available gap length. Pe is the Peclet number and δ the height of leakage gap. Therefore the existing flow may be considered fully developed. For power law fluids, numerical calculations lead to results of the same order. Martin's results therefore may be applied to the flow at the exit of the leakage gap.
Item Type:Article
Copyright:© 1978 Wiley InterScience
Link to this item:http://purl.utwente.nl/publications/70747
Official URL:http://dx.doi.org/10.1002/pen.760180409