Dc and ac behaviour of a normal joint in a superconducting cable

Share/Save/Bookmark

Reuver de, J.L. and Kate ten, H.H.J. and Knoopers, H.G. and Klundert van de, L.J.M. (1984) Dc and ac behaviour of a normal joint in a superconducting cable. Cryogenics, 24 (5). pp. 251-256. ISSN 0011-2275

[img]
Preview
PDF
429Kb
Abstract:The application of joints which can be disassembled is studied within the framework of the development of high current (25 kA), high power (0.5 kW) cryogenic current supplies (flux pumps).1,2 The behaviour of a scale model with currents up to 5 kA will be presented here.

Several means of diminishing the joint resistance have been researched with special attention being paid to detection methods to measure the resistance, and their accuracies.

The role of the solder has been investigated. A simple model gives good qualitative understanding of the matter.

The presence of ac currents in a cryogenic current supply causes considerably higher losses in the joint because of the non-homogeneous distribution of the current. A good impression of this distribution can be obtained by measuring the field along the joint. The measured results are in good agreement with calculated ones. A useful length of the joint under ac conditions can be defined and is helpful for design purposes.
Item Type:Article
Copyright:© 1984 Elsevier Science
Faculty:
Science and Technology (TNW)
Research Group:
Link to this item:http://purl.utwente.nl/publications/69364
Official URL:http://dx.doi.org/10.1016/0011-2275(84)90152-8
Export this item as:BibTeX
EndNote
HTML Citation
Reference Manager

 

Repository Staff Only: item control page