Modelling motor cortex stimulation for chronic pain control. electrical potential field, activating functions and responses of simple nerve fibre models

Share/Save/Bookmark

Manola, L. and Roelofsen, B.H. and Holsheimer, J. and Marani, E. and Geelen, J.A.G. (2005) Modelling motor cortex stimulation for chronic pain control. electrical potential field, activating functions and responses of simple nerve fibre models. Medical and biological engineering and computing, 43 (3). pp. 335-343. ISSN 0140-0118

[img]PDF
Restricted to UT campus only
: Request a copy
1577Kb
Abstract:This computer modelling study on motor cortex stimulation (MCS) introduced a motor cortex model, developed to calculate the imposed electrical potential field characteristics and the initial response of simple fibre models to stimulation of the precentral gyrus by an epidural electrode, as applied in the treatment of chronic, intractable pain. The model consisted of two parts: a three-dimensional volume conductor based on tissue conductivities and human anatomical data, in which the stimulation-induced potential field was computed, and myelinated nerve fibre models allowing the calculation of their response to this field. A simple afferent fibre branch and three simple efferent fibres leaving the cortex at different positions in the precentral gyrus were implemented. It was shown that the thickness of the cerebrospinal fluid (CSF) layer between the dura mater and the cortex below the stimulating electrode substantially affected the distribution of the electrical potential field in the precentral gyrus and thus the threshold stimulus for motor responses and the therapeutic stimulation amplitude. When the CSF thickness was increased from 0 to 2.5 mm, the load impedance decreased by 28%, and the stimulation amplitude increased by 6.6 V for each millimetre of CSF. Owing to the large anode-cathode distance (10 mm centre-to-centre) in MCS, the cathodal fields in mono- and bipolar stimulation were almost identical. Calculation of activating functions and fibre responses showed that only nerve fibres with a directional component parallel to the electrode surface were excitable by a cathode, whereas fibres perpendicular to the electrode surface were excitable under an anode.
Item Type:Article
Copyright:© 2005 Springer
Faculty:
Electrical Engineering, Mathematics and Computer Science (EEMCS)
Research Group:
Link to this item:http://purl.utwente.nl/publications/63816
Official URL:http://dx.doi.org/10.1007/BF02345810
Export this item as:BibTeX
EndNote
HTML Citation
Reference Manager

 

Repository Staff Only: item control page

Metis ID: 224257