Time constants for switching flow in left ventricular output impedance


Share/Save/Bookmark

Boom, Herman B.K. and Wijkstra, Hessel (1989) Time constants for switching flow in left ventricular output impedance. In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1988, 4-7 Nov 1988 , New Orleans, Louisiana.

[img]
Preview
PDF
140Kb
Abstract:Pressure curves obtained in isolated rabbit hearts after the end of externally imposed constant flow pulses were divided by isovolumic pressure curves at the same volume. An exponential decay to a constant level, generally lower than one, was observed. The time constant equaled that found for switching-on of the flow pulse. The results indicate that flow deactivation can be described as a decrease of ventricular elastance.